Polarimeter Research Digital

AR-1007j

Indian Imported


Price : Rs 0 eachSend Enquiry
 
   
   
 

Polarimeter Research Semi Automatic

AR-1007.11


Price : Rs 0 eachSend Enquiry
 
   
   
 

Polarimeter Research 400mm tube + SV Lamp set

AR-1007d

AR-1007d

An improved optical system with half shadow system. Permanent focus i.e. to say, once the dividing line is focused to suit the eye, this focus is never disturbed by inserting tubes of sugar or other solutions, regardless of the fact that they may not be completely homogeneous, or of the length of the tube.
Scale : Angular 0 - 360' subdivided to 1' Micrometer drum enabled direct reading to 0 - 5' and by estimation 0 - 2'.
Sugar :-30 to +120 ISS, Micrometer drum enables reading to 0 - 1 sugaran improved optical system with half shadow system. Telescope magnification :5x. Range of measurement :+ 10'to +110'

OPTIONAL Sodium Vapour Lamp SV lamp with chock Transformer and box with slits


Price : Rs 0 eachSend Enquiry
 
   
   
 

Polarimeter Research Spare Tube 400 mm

AR-1007e


Price : Rs 0 eachSend Enquiry
 
   
   
 

Polarimeter Research Tube 200 mm Tube

AR-1007b


Price : Rs 0 eachSend Enquiry
 
   
   
 

Polarimeter Tube 200 mm

AR-1004c

With bulb in the centre, 200 mm in velvet lined case.The ends of the tubes are threaded to receive-the interchangeable cap


Price : Rs 0 eachSend Enquiry
 
   
   
 

Polarizer and Analyser Set of 2 in Slide Abron

AR-1031

Set in 50x50 mm slides mounted to fit laser lens holder


Price : Rs 0 eachSend Enquiry
 
   
   
 

Quarter Wave Plate for Babinets Compensator

AR-1000c

with Mount for above


Price : Rs 0 eachSend Enquiry
 
   
   
 

Rayleigh Interferometer Abron for Gas Cells

AR-1019.02

For determination of change in refractive index in liquid and gases of the order of 10-8.

ESSENTIAL ACCESSORIES

(i) Plane-parallel optical glass cell with mechanical mount.

(ii) Pair of gas cell with plane-parallel windows.

(iii) Manometer with mini vaccum pump.

(iv) Sodium Lamp with transformer and choke.

GAS CELLS For liquids or tube for Gases


Price : Rs 0 eachSend Enquiry
 
   
   
 

Rayleigh Interferometer Abron for Liquids

AR-1019.01

For determination of change in refractive index in liquid and gases of the order of 10-8.

ESSENTIAL ACCESSORIES

(i) Plane-parallel optical glass cell with mechanical mount.

(ii) Pair of gas cell with plane-parallel windows.

(iii) Manometer with mini vaccum pump.

(iv) Sodium Lamp with transformer and choke.

For RI of Liquids & Gases to the order of 10


Price : Rs 0 eachSend Enquiry
 
   
   
 

Research Optical Bench Lythe Type 170cm Abron

AR-1008

Digital LED with AAA Cell Operated

With Maximum and Minimum Point recording in 24 hour

With external temperature probe

It is meant for Research works. Lythe type 170 cms long. A heavy cast iron bed with a strong central rib, thoroughly seasoned and aged before machining and grinding of its upper surfaces. Total length 180 cms; with a machined full length platform for the scale. The scale is from lifetime stainless steel fitted on its machined platform on the bed. Divided in mms to a length of 170cms. Accuracy of calibration + 0.01%. Riders are provided to carry the standard experimental accessories. Under-surfaces of riders are machined true to fit the machined bed surface, and these machined surfaces are then jointly underground to give perfectly smooth sliding surfaces. Stainless venires fitted to the riders read the scale to .01 cm. The Bi-prism rider is also provided with fine cross motion read by Vernier to .01 cm.

(i) Optical Slit :With finely ground stainless jaws. Manipulation of jaw movement free from any spring control ensuring maintenance of original accuracy even after prolonged use. The following adjustments are provided for the slit and its carriage.

(a) Linear adjustment along the bed, read by Vernier to .01 cm.

(b) Fine vertical adjustment by slow motion screw.

(ii) Bi-Prism Holder : Provided with the linear adjustment and fine cross motion by micrometer screw (Vernier - .01 cm).Coarse and fine radial motion along the horizontal axis.

(iii) Micrometer Eye Piece : Provided with coarse and fine linear adjustment (Vernier = .01 cm).

Micrometer cross motion of the Eyepiece along a 30 - 0 - 30 mm scale read on a micrometer head to 0.001 cm. Micrometer head fitted with antiback-lash device


Price : Rs 0 eachSend Enquiry
 
   
   
 

Susceptibility of Paramagnetic Solids by Gouys Method

AR-1022

We offer Apparatus for Measurement of Susceptibility of Paramagnetic Solids by Gouy’s Method in this, the solid sample in the form of a long cylinder (area of cross section A) is hung from the pan of a balance and is placed such that one end of the sample is between the pole-pieces of the magnet (field H ) and the other one is outside the field. The force exerted on the sample by the inhomogeneous magnetic field is obtained by measuring the apparent change (Δm ) in the mass of the sample. The susceptibility χ is given by χ = 2Δmg/AH2
If the sample is in the form of powder, it is filled in a long nonmagnetic tube which is then suspended from the pan of the balance.
The set up consists of the following:
(a) Scientific Balance, Capacity: 200 gms Sensitivity: 1/10 mg.
(b) Sample in the form of a long rod: Set of 4 samples, 2 each of Ebonite and Wood
(c) Electromagnet, Pieces: 75mm tappered to 25mm Mag. Field: 20KG at 6mm airgap Energising Coils: Two of approx. 13Ω each Power: 0-90Vdc, 3A, for coils in series 0-45Vdc, 6A, for coils in parallel
(d) Constant Current Power Supply, Current: 0-3A per coil Smoothly adjustable Line Regulation: 0.1% for 10% mains variation Load Regulation: 0.1% for load variation from 0 to max.Display: 3 digit, 7 segment LED display Protection: Protected against overload, short circuit and transients caused by the load inductance. Power: 220V 10%, 50Hz or 110V 10%, 60Hz as required.
(e) Gaussmeter,
The experiment is complete in all respect


Price : Rs 0 eachSend Enquiry
 
   
   
 

Travelling Microscope Deluxe Three Motion

AR-1009b

For certain measurement it is found more convenient to provide sliding motion to the microscope tube across the stage, in addition to all other usual movements. (This microscope is very useful in Newton ’s ring experiment and graph reading etc.). A sliding carriage is fitted on the top carriage which moves at the right angle to the horizontal motion by means of rack and pinion. This motion is also graduated in millimetres having Vernier reading of 0.1 mm. Supplied in a superior quality wooden box


Price : Rs 0 eachSend Enquiry
 
   
   
 

Travelling Microscopes Deluxe 2 motion, S.S. Scale

AR-1009.01

Base : Property painted heavy cast iron base, with two levelling screws. Top surface is machined for smooth sliding of carriage having clamping screws for locking.
Horizontal Scale : Stainless Steel length of 0 to 20 cm in 0.5 mm division.
Vertical Scale : Brass a length of 14 cm graduated in 0.5 mm division. Horizontal and Vertical venires, both have divided in 50 divisions.
Microscopes : Microscope fitted on a vertical carriage can be clamped in vertical or horizontal plane.
Objective and Eye Piece : Consisting of 10x Rams den eye piece and 2" or 3" focal length objective made from highest quality optical glass


Price : Rs 0 eachSend Enquiry
 
   
   
 

Ultrasonic Interferometer Abron Multi Frequency 1,3,5,7

AR-1020b

Frequency Range: multi

Accuracy: + 0.03 %


Price : Rs 0 eachSend Enquiry
 
   
   
 

Ultrasonic Interferometer Abron Multi Frequency 8 Range

AR-1020c

Frequency Range:1, 2, 3, 4, 5, 6, 10 & 12 MHz

Accuracy: + 0.03 %


Price : Rs 0 eachSend Enquiry
 
   
   
 

Ultrasonic Interferometer Abron Single Frequency 2MHz

AR-1020a

Single Frequency, Lab Model)

Frequency Range: 2 MHz

Accuracy: + 0.3 %


Price : Rs 0 eachSend Enquiry
 
   
   
 

Zeeman Effect APP. with Prism

AR-1021

e/m by Zeeman’s Effect Apparatus
The apparatus consists of the following items
(i) Constant deviation spectrograph-1 No.
Calibration range:4000-A-7000 A 10A
(ii) Constant deviation spectrograph prism (μ= 1.71)-1 No.
(iii) Fabry-Perot Etalon.Clear aperture: 25 mm-1 No.
(iv)Micrometer eyepiece.Measuring Range: 25 mm; LC: 0.01mm-1 No.
(v) Electromagnet having field strength 10 kilo Gauss at 10 mm gap between its pole-1 No.
(vi)Constant current Power supply for above electromagnet-1No.
(vii) Neon discharge tubes-2 Nos.
(viii) Wooden stand with clamp for holding discharge tube-1 No.
(ix) High voltage transformer to run the above discharge tubes-1 No.
(x) Digital Gauss meter with probe 1 No


Price : Rs 0 eachSend Enquiry
 
   
   