info@abronexports.com, info@abron.in
 
   
 
askaquestion
 
 

105 - Industrial Estate,
Ambala Cantt-133001,Haryana (India)

E-mail- info@abronexports.com

Click Here For More Details

Online Support
skypmsnfacebook
indiaflagglobe

 

Electronic Instruments

A |B |C |D |E |F |G |H |I |L |M |N |O |P |R |S |T |U |V |W |Z |
1 | 2 | 3 | 4 | 5 | 6 | [«Back || | Next »] |
 

Elliptically Polarised Light Abron Cell Setup

AE-1257A


Price : Rs 0 eachSend Enquiry
 
   
   
 

Elliptically Polarised Light Spectrometer

AE-1257B


Price : Rs 0 eachSend Enquiry
 
   
   
 

EMF of A Thermocouple Abron

AE-1260

Complete with Manual and Connection Wire.


Price : Rs 0 eachSend Enquiry
 
   
   
 

EMFs. of Two Cells Comparison Abron

AE-1259

Complete with Manual and Connection Wire.


Price : Rs 0 eachSend Enquiry
 
   
   
 

Emitter Follower

AE-1258-12

One fixed IC regulated power supply, transistor in CC mode with associated components, test points in socket form. Complete with Manual and Connection Wire.
Optional:AC Milivoltmeter and audio oscillator.


Price : Rs 0 eachSend Enquiry
 
   
   
 

FET CH. Apparatus Abron

AE-1270

With power supply 2 meters To study the characteristics of Field Effect Transistor.

The apparatus consists of four parts :

(i)

Measurement of IDSS

(ii)

Drain Current v/s Drain Voltage

(iii)

Drain Current v/s Drain Bias characteristics Power Supply One 0 - 5 V DC variable at 30 mA Stabilised One 0 - 10 V DCvariable at 30 mA Stabilised Meter 10V / 5V AC and 10 V Ammeter 20 mA FET Provided with terminals mounted on the panel ON / OFF Switch, Jewel Light Complete with Manual and Connecting Wire


Price : Rs 0 eachSend Enquiry
 
   
   
 

Fiber Optic LED'S

AE-1269-05

Objectives of this experiment : Demonstrate the silimarities and differences between conventional LED's and Fibre Optic LED's. Built-in regulated power supply + 5V DC / 500 mA, + 15 V DC / 250 mA


Price : Rs 0 eachSend Enquiry
 
   
   
 

Fiber Optic Simplex Link

AE-1269-06

Objectives of this experiment :In this experiment, you will learn how to attach simplex connectors to a fiber optic cable. Then you will build a transmitter and receiver circuit and investigate the operation of a simplex link. Built-in regulated power supply + 5V DC / 500 mA, + 15 V DC / 250 mA


Price : Rs 0 eachSend Enquiry
 
   
   
 

Fiber Optics Educational Kit

AE-1269-06

Objectives of this experiment :In this experiment, you will construct a full-duplex Fiber Optic Link, usig dual fibre optical cable. It is ussed to transmit the "digital" signal produced by '555' timer through fibre optic cable.Built-in regulated power supply @ + 5 V DC / 500 mA.
Specifications :Fiber Optic Educational Kit is an introductin to Fiber Optic Communicatins. No prior experience is required to operate it. It contains all the components for building fiber optic data link including a LED, Detector, Fiber Optic Connectors, Interface Electronics and one meter of Fiber Optic Cable. Termination of the plastic fiber optic cable requires the use of just a simple, sharp knife. The instruction booklet covers the theory of operation, assembly instructions, references glossary and some simple experiments. It is the ideal kit for beginners, hobbyists or a student of fiber optics. This fiber optic link can be extended upto 16 meters, making it useful for & short-distance optical isolation applications,constructing RS 232 interfaces and science fair projects.
Features :*Integrated Devices & Connectors.*One Minute Fiber Terminations.*Transmitter Oscillator for Testing.*Matched Emitter and Detector *TTL / CMOS Input Compatible.
Accessories :*Fiber Cable *Polishing Film *Printed wiring boards *Interface Electronics *Instruction booklets.


Price : Rs 0 eachSend Enquiry
 
   
   
 

Fiber Optics Test Kit Abron Fiber Optics Special benc

AE-1269-01

Plate form, attachments


Price : Rs 0 eachSend Enquiry
 
   
   
 

Fillers Circuit Using LCR Abron

AE-1271

Complete with Manual and Connecting Wire.


Price : Rs 0 eachSend Enquiry
 
   
   
 

Flip Flops Training Boards D Type

AE-1272A

This is very useful for understanding experiment with box and circuit engraved on panel with test 4mm banana plug sockets


Price : Rs 0 eachSend Enquiry
 
   
   
 

Flip Flops Training Boards Flip Flop R.S., D & JK

AE-1272D

This is very useful for understanding experiment with box and circuit engraved on panel with test 4mm banana plug sockets


Price : Rs 0 eachSend Enquiry
 
   
   
 

Flip Flops Training Boards Jk

AE-1272B

This is very useful for understanding experiment with box and circuit engraved on panel with test 4mm banana plug sockets


Price : Rs 0 eachSend Enquiry
 
   
   
 

Flip Flops Training Boards R.S.

AE-1272C

This is very useful for understanding experiment with box and circuit engraved on panel with test 4mm banana plug sockets


Price : Rs 0 eachSend Enquiry
 
   
   
 

Free Running Vibrator

EC-396-04

In-built regulated DC power supply, timer IC NE 555, 5R, three C for different time periods, one monopulser, one buffered LED, one potentiometer. Complete with Manual and Connection Wire.
Optional:C. R. O., frequency counter and audio oscillator.


Price : Rs 0 eachSend Enquiry
 
   
   
 

Frequency CH OF RC. Coupled Amplifer

AE-1273-01

Complete with Manual and Connecting Wire


Price : Rs 0 eachSend Enquiry
 
   
   
 

Frequency CH of RC. Coupled Amplifer with VTVM

AE-1273-02

Complete with Manual and Connecting Wire


Price : Rs 0 eachSend Enquiry
 
   
   
 

Frequency Counter

AE-1316d

Indication Six Digit Led Display, 0.5 Inch High.
Frequency Range Reads Upto 50.0000 Mhz With A Resolution Of 1 Hz.
Input Sensitivity 50mv Upto 15mhz.125mv For Frequency 15mhz To 50mhz.
Maximum Input Voltage 100v P/P.
Gate Period 1 Sec.; 0.1 Sec.; 0.01 Sec.
Accuracy 0.005%, + 2 Digit.
Power Requirement 220v, + 10%, 50hz


Price : Rs 0 eachSend Enquiry
 
   
   
 

Function Generator Abron 1 Hz-100 KHz

AE-1353A

Sine, Square Triangular wave, Input power 230 V AC 50Hz + 10% Power consumption 10 watt approx. Output Freq.: 1 Hz to 100KHz by mean of 5 position, decade multiple and continuously variable dial.Accuracy dial + 2% scale +1 deg. Output Amplitude Sine and triangle 1mV to 30 upp (WL) -1db. Dis sine Square .1V to 30Vpp (WL) Square Wave (D.F Less than 1% (1KHz) 50.50 (useable 100Hz to 10km) +2% Sg wave Rise/Fall time : RT 180 ns.FT 40 ns Tringle wave linearity Within 2% from 50Hz to 50 KHz. Output impedance 50 ohms.


Price : Rs 0 eachSend Enquiry
 
   
   
 

Function Generator Abron 10 Hz - 500 MHz

AE-1353B

Function controls :

Selects output Sine / Square / Triangular.

Range :

It selects the Frequency output at position OFF, no output. At position XI, the frequency is variable 1 Hz to 10 Hz. At position XIO, variation is 10 Hz to 100 Hz. At position XIOO variation is 100 Hz to 1000Hz. At position 1 K is variable 1 KHz to 10 KHz and at position 10 K, It is variable to KHz to 100 KHz. The fine variation is done by control marked FINE.

Level :

This is attenuator for output and the switch marked 1, 2, 3 is coarse control and the other is vernier. Mains 220 V 50 Hz Frequency 1 Hz to 100 KHz Wave Form Sine / Square / Triangular Accuracy + 2% Stability + .5% Output 0 - 10 VPP Output Impedance 50 ohms

General :

The instrument is fully solid state IC version. The Power Supply used is highly stabilised and ensure good stability.

Operating Instructions for Pulse Generator :


Price : Rs 0 eachSend Enquiry
 
   
   
 

Function Generator Abron 1Hz-1MHzAbron Sine, Square, Triangle wave

AE-1353b

The FUNCTION GENERATOR’ is capable of Providing SINE,
SQUARE, TRIANGLE Wave Form. It has a linear Frequency Scale
very low Distortion & constant signal amplitude with the output Signal
Symmetry about Zero. The DC coupled output provides square wave
without any appreciable Sag at low frequency.It has a maximum 20 VP/P amplitude.
The output is protected against short circuit. It has a offset control provided to shift the
base line of Signal by + 10 volts. The continuously variable DC offset control further
enhance the versatility of the Instrument.
The equipment is used in Audio Electronics and other Laboratory & Research Work. FREQUENCY RANGE 0.1 Hz to 1MHz in six decade Range.
DEAL ACCURACY + 5% Of Range AMPLITUDE 0-20V P/P for all Function.
WAVE FORMS SINE, SQUARE & TRIANGLE. SINE WAVE DISTORSION
Less than 1% from 100Hz to 100KHz SQUARE WAVE DUTY CYCLE
49% TO 51% SQUARE WAVE RISE TIME : Less than 100 nano Sec.
at Maximum Amplitude.
OUTPUT IMPEDANCE 600 Ohm + 5% Power 230V + 10% AC

Price : Rs 0 eachSend Enquiry
 
   
   
 

Function Generator Digital 1Hz-1MHz Sine, Square, Trianle

AE-1353-C

• Excellent wave shape, signal linearity and wave from symmetry.

• Wide frequency range from 0.01Hz to 1MHz

• Commendable frequency and amplitude stability.

• Voltage controlled frequency sweeping facility.

• Separate TTL / CMOS Output and facility of DC offset FREQUENCY RANGE 0.01 Hz to 1MHz in suitable steps.

FUNCTION:

Sine, Square, Triangle, Ramp, Pulse, TTL/CMOS pulse output.

DISPLAY Digital:

(4Digit 7 segment display) ACCURACY Better than +_ 1% + 3 digit of F.S.

AMPLITUDE:

30V p - p into open circuit.

AMPLITUDE CONTROL:

0 to 60 dB variable (2 x 20 dB fine)

DC OFFSET:

Up to +_15V into open circuit, continuously variable independent control.

OUTPUT IMPEDANCE:

250 Ohm & 600 Ohm Switchable

POWER REQUIRED:

230V +_ 10 AC


Price : Rs 0 eachSend Enquiry
 
   
   
 

G.M. Counter Abron Only End Window G.M. Deterctor.

AE-1280-02

(Helogen quenched)Geiger - Muller radiation counted tube (G. M. Tube) are intended to detect Alpha particulars, Beta particulars, Gamma or X-radiation.G. M. Tube consists of basically an electode at a positive potential (anode) surrounded by a metal cylinder at a negative potential (cathode). The cathode forms part of the envelope or is enclosed in a glass envelope. Tonizing events are initiated by quanta or particles entering the tube either through the window or through the cathode and colliding with gas molecules. The gas filling consists of a mixture of one or more rare gases and a quenching agent. Quenching is the termination of the ionization current pulse in a G. M. Tube. Effective quenching in our tube is determined by the combination of the quenching gas properties and the value of the anode resistor.


Price : Rs 0 eachSend Enquiry
 
   
   
 

G.M. Counter complete setup Abron (Gerger Counting System) 6 digit

AE-1280-10

Setup Instrument consists of power supply for G.M. Tube with digital read out meter. 6 Digit counting system with its power supply. Controls for reset, start and stop through on panel. One presetable timer with 3 digit display and thumb wheel switch. Complete with G.M. Tube, stand, and one radio active source B


Price : Rs 0 eachSend Enquiry
 
   
   
 

G.M. Counter Gerger Counting System) 6 digit only setup

AE-1280-01

G.M. Counter with Built in Power Supply


Price : Rs 0 eachSend Enquiry
 
   
   
 

G.M. Counter Only Aluminium/LEAD absorber disc set

AE-1280-05

Aluminium and Lead or Sheets of Different Thickness are provided for taking reading of radiation through disc. The sizes are as per our stand. Generally 2" x 3" or 2" x 4"


Price : Rs 0 eachSend Enquiry
 
   
   
 

G.M. Counter Only Lead sheet for Body

AE-1280-06

Heavy Lead Metal embedded Apron is given similar to X-Ray Machine users apparatus to avoid radiation to the technical demonstrator. The complete setup can be supplied by us with all the items suitable, tested and designed for easy operation and The Instrument setup is supplied complete with Manual


Price : Rs 0 eachSend Enquiry
 
   
   
 

G.M. Counter Only Stand for above

AE-1280-03

C. STAND FOR G. M. TUBE : It is a thick perspe stand where G. M. Tube can be placed on the top. The place cut is as per G. M. Tube supplied by us. The stand also has the MT Space for keeping ratio active source it also has the grooves for placing the Different Absorbers of Aluminium and LED etc.


Price : Rs 0 eachSend Enquiry
 
   
   
 

Gauss Meter Analog

AE-1278-02

Operates on the principle of Hall Effect in Semi-conductors. A Semi-conductor material carrying current develops an electro-motive force, when placed in a magnetic filed, in a direction perpendicular to the direction of both electric current ahd magnetic field. The magnitude of this e.m.f. is proportional to the field intensity of the current is kept constant, this e.m.f. is called the Hall Voltage. This small Hall Voltage is amplified through a high stability amplifier so that a millivoltmeter connected at the output of the amplifier can be calibrated directly in magnetic field unit (Gauss).
Applications : Wide application in industry where accurate measurements of magnetic field is required. Measurement of steady magnetic field e.g. in loud speakers, dynamos, moving coil intruments etc Useful in laboratory experiments involving electromagnets.
Meter Analog Rectangular 100 mm Range 0-25 Kilo Gauss 4 Ranges Probe Special Probe Provided Complete with Manual.


Price : Rs 0 eachSend Enquiry
 
   
   
1 | 2 | 3 | 4 | 5 | 6 | [«Back || | Next »] |
 

 
 